Is It Time for a Roof Replacement? The Top 5 Signs Your Wichita Roof is Failing

Deciding between a minor roof repair and a full roof replacement is one of the biggest decisions a commercial property owner or manager faces, and spotting the critical warning signs early is the key to preventing financial disaster and protecting your property. Ignoring a failing roof in Wichita means risking catastrophic leaks during our harsh winter, causing severe damage to your building’s interior, valuable inventory, and critical equipment. Use this guide to help you recognize the five biggest red flags that mean it’s time to call Solid Rock Commercial Roofing.

What is the first sign that my commercial roof might need replacing?

If you are seeing multiple leaks inside your building, or leaks that keep popping up in new places after repair, it’s a strong signal that the entire roofing system is failing and cannot be spot-fixed anymore. These constant water intrusions often point to major, widespread deterioration beneath the surface of the roof membrane. When water damage is no longer isolated to one area, it means the roof structure itself is compromised, making replacement the safer and far more cost-effective choice than trying to chase endless, recurring leaks.

Trying to fix a system that has reached the end of its life is like constantly patching a worn-out tire—it only buys you a little time before the next blowout. A single roof patch might cost $500, but if you need five of those patches in one year, that $2,500 could have been better invested in a new system that comes with a long-term warranty. When the average life expectancy of the roofing material has passed, and leaks are showing up in three or more unrelated spots, the wise choice is always replacement.

How does the visible condition of the membrane or materials show I need a new roof?

When the top layer of your membrane roof (like TPO or BUR) starts to look dry, brittle, cracked, or like an alligator’s hide, the material has lost its essential flexibility and waterproofing ability, meaning it can no longer protect your building from the Kansas weather. This visible breakdown is a sign that the protective layer has been destroyed by years of UV radiation and the constant movement from temperature changes.

  • Cracking and Splits (TPO/PVC/EPDM): These systems rely on being flexible. If you see straight lines or star-shaped breaks in the membrane, especially near the corners or edges, it means the plasticizers have dried out, and the material has become brittle. A contractor might call this loss of tensile strength. For instance, a quality TPO membrane is designed to stretch and move; a failing membrane will simply snap when exposed to thermal stress, leading to an immediate leak.
  • Alligatoring (BUR/Asphalt): On older built-up roofs (BUR) or modified bitumen, the surface develops a pattern that looks exactly like alligator skin. This happens when the asphalt binder becomes severely oxidized and brittle. Once a roof reaches this stage, it will rapidly lose its weather protection, and patching is ineffective because the new patch cannot bond to the oxidized, crumbling material.

The visual signs of material failure are the clearest physical proof that your roof is ready for retirement.

Why is a high utility bill a sign of roof failure, and not just bad HVAC?

If your energy costs have suddenly spiked, or if the roof feels soft and spongy to walk on, it often means the insulation beneath the membrane has become wet and is no longer stopping heat transfer, which forces your HVAC system to work much harder to keep the interior temperature stable. Roof insulation is designed to keep heat inside in the winter and outside in the summer, but when it gets soaked from a small leak, it loses almost all its R-value (its ability to resist heat flow).

For example, rigid foam insulation might start with an R-value of R-12 when dry. Once that insulation becomes waterlogged, its R-value can drop by as much as 90% [Source: Roofing Industry Committee on Weather Issues Study]. A wet, failed roof is effectively an energy sieve, costing you significant money every month. The only way to fix wet insulation is to remove the entire roof system, replace the wet material, and install a new membrane. If you notice a spongy feel when walking on your roof, you should treat it as an emergency, as that sponginess is saturated insulation waiting to cause mold and structural decay.

What do major issues around flashings and penetration points tell me?

Significant rust, broken seals, or widespread gaps where the roof membrane meets pipes, vents, or walls (collectively known as flashings) indicate that the most critical waterproofing components of your roof have failed, and once these seals break down across the roof, a full replacement is often necessary. Flashings are the roof’s weak points because they involve different materials—like the plastic membrane meeting a metal pipe—that expand and contract at different rates.

Look for these signs around HVAC curbs, exhaust vents, and parapet walls:

  1. Gapping or Detachment: If you can see light or a noticeable gap between the flashing material and the equipment it’s meant to seal, the system has failed.
  2. Rusted Metal: If the metal supports for your rooftop equipment are severely rusted, it means water has been sitting there for a long time, suggesting the seal underneath has been breached. Rust is a clear sign that water is not draining properly and has been allowed to sit and corrode the metal components.
  3. Widespread Caulking Failure: If a maintenance crew has tried to seal every flashing point with temporary sealant or caulk, and those patches are peeling, it proves the underlying membrane is too old or brittle to hold a permanent weld. At this stage, you need a whole new system with fresh, pliable flashings and a durable membrane.

When does the age of my roof alone justify replacement?

If your commercial roof has already lasted through its typical lifespan—for example, 15-20 years for TPO, 20-30 years for PVC, or 40+ years for metal—it is time to consider replacement before it suffers a major, costly failure, even if it looks okay from the ground. While rigorous maintenance can extend a roof’s life, all materials have a predicted service limit, and choosing to replace on schedule avoids the sudden, expensive surprises of catastrophic failure in the middle of winter.

What are typical commercial roof life expectancies?

Here are some typical life expectancies for common commercial roofing types, though factors like installation quality and maintenance can shift these numbers:

Material TypeTypical Life ExpectancyReplacement Justified After…
Single-Ply (TPO/EPDM)15 – 25 Years18 Years, if leaks start appearing
Single-Ply (PVC)20 – 30 Years25 Years, especially in high-traffic areas
Built-Up Roof (BUR)15 – 25 Years20 Years, or when alligatoring becomes widespread
Metal Roofing30 – 50+ YearsWhen protective coatings fail and widespread rust occurs

If your roof is approaching the higher end of its expected life, you should prioritize its replacement in your budget, as the risk of catastrophic failure increases every year after the 20-year mark. Planning for replacement allows you to budget correctly and select materials during mild weather, avoiding emergency winter prices.

Frequently Asked Questions (FAQs)

If I only see mold on my interior ceiling, does that mean I need a new roof?

Yes, interior mold or mildew growth is a serious red flag because mold needs a continuous moisture source to survive, which means water is definitely getting through your roof deck and into your building materials. If the water intrusion is severe enough to feed mold growth, the leak is likely significant and has been going on for some time, possibly rotting the underlying wood or insulation. A full roof replacement is often needed to stop the leak, remove all the contaminated materials, and ensure the mold source is permanently eliminated.

Can a roof coating save me from a full replacement?

Sometimes, a roof coating can buy you a few extra years, but only if the roof substrate (the layer underneath) is dry and structurally sound. A coating acts like a big layer of paint, restoring the reflective qualities and UV protection to a sound membrane. However, if your roof already has wet insulation, major cracks, or structural issues, a coating will only seal the water in, making the hidden damage worse. Solid Rock Commercial Roofing will always perform a thorough inspection and moisture test to determine if a coating is a realistic option, or if replacement is the only safe solution.

What is the most expensive type of damage caused by waiting too long to replace a roof?

The most expensive damage is usually structural damage to the roof deck itself and damage to interior inventory or equipment. For example, if a major winter leak floods your server room, the cost of replacing specialized electronic equipment can reach tens of thousands of dollars, far exceeding the cost of the roof replacement. Furthermore, if water soaks the wood roof deck repeatedly, it can lead to rot, which requires highly specialized and costly structural repairs, making the overall replacement project much more expensive and time-consuming.

Final Thoughts & Call to Action: Secure Your Future

Your commercial roof is your building’s most important defense against the harsh Wichita weather. By paying close attention to the top five failure signs—multiple leaks, brittle materials, soaring energy bills, broken flashings, and old age—you can take control of your asset management. Replacing a roof on your schedule, during the mild fall months, is always safer and more affordable than dealing with a panicked emergency replacement in the snow and ice. Don’t risk a crippling winter disaster.

Contact Solid Rock Commercial Roofing today for a thorough, professional roof inspection. Our Wichita-based experts will provide you with an honest assessment of your roof’s condition, giving you the facts you need to make the best decision for your business’s future security.

Call us to schedule your inspection and get a clear path to protecting your commercial investment.

author avatar
Rusty Cryer CEO
Rusty gets excited about meeting customer needs and developing long-term relationships. Over the past several years God has blessed Rusty with a team that comprises over 65 years of commercial roofing experience. They have been able to lead a variety of amazing roofing projects in south central Kansas.-